Last edited by Malami
Thursday, August 6, 2020 | History

2 edition of Testing of glass volumetric apparatus found in the catalog.

Testing of glass volumetric apparatus

National Bureau of Standards.

Testing of glass volumetric apparatus

by National Bureau of Standards.

  • 45 Want to read
  • 19 Currently reading

Published by U.S.G.P.O. in Washington .
Written in English


Edition Notes

Statementby J.C. Hughes.
SeriesN.B.S. circular -- 602
ContributionsHughes, J C.
ID Numbers
Open LibraryOL20217060M

Introduction to Medical Laboratory Technology presents the development in the medical laboratory science. It discusses the general laboratory glassware and apparatus. It addresses a more specialized procedure in mechanization, automation, and data processing. Principle: This is a full-scale room test. Test Apparatus: Burn room, no specific size, but at least × × m high; thermocouple (unspecified gauge) over the center of the chair, m above the floor. (This could make it exactly on the ceiling; it is presumed the actual procedure used involves placing it slightly below the ceiling.).

Full text of "IS/ISO Laboratory Glassware - Volumetric Instruments - Methods for Testing of Capacity and for Use" See other formats ***** ^ tOTH: Disclosure to Promote the Right To Information Whereas the Parliament of India has set out to provide a practical regime of right to information for citizens to secure access to information under the control of public authorities, . Droplets of the reagent solution on the surface of the greasy glass. It is impossible to account for volume of these droplets, so you will never know what volume of the reagent was used - and as the precision of the volume measurements is the basis of the precision of the volumetric methods, dirty volumetric glass means huge errors.

A volumetric flask is intended to measure a specific volume with a high level of accuracy. Typical sizes include ml and ml. Because volumetric flasks are precision glassware, they are expensive to replace. Handle with care!Author: Anne Marie Helmenstine, Ph.D.   Glass and Plastic Labware used to Measure Volume• Volumetric Flasks – Proper use • Choose the proper type of flask for the application – TC or TD – Class A or Class B – Serialized or not • Be sure the flask is completely clean before use • Read the meniscus with eyes even with liquid surface • If calibrated TD, then pour as.


Share this book
You might also like
Windows Development on Netware

Windows Development on Netware

razors edge

razors edge

Degree course guides

Degree course guides

Grandma Moses

Grandma Moses

Why Kill Mildred?

Why Kill Mildred?

Veronica and the birthday present

Veronica and the birthday present

Census of India, 1991.

Census of India, 1991.

The Boston cooking-school cook book

The Boston cooking-school cook book

Writing while under the influence

Writing while under the influence

Life and teachings of Rev. T. De Witt Talmage

Life and teachings of Rev. T. De Witt Talmage

On the atomic weight of nickel

On the atomic weight of nickel

Fluid Dynamics Panel Working Group 12 on Adaptive wind tunnel walls technology and applications.

Fluid Dynamics Panel Working Group 12 on Adaptive wind tunnel walls technology and applications.

Value theory and business cycles

Value theory and business cycles

Testing of glass volumetric apparatus by National Bureau of Standards. Download PDF EPUB FB2

Testing of glass volumetric apparatus [Hughes, John Chapman] on *FREE* shipping on qualifying offers. Testing of glass volumetric apparatus. Testing of glass volumetric apparatus [United States. National Bureau of Standards.] on *FREE* shipping on qualifying offers.

Additional Physical Format: Online version: Testing of glass volumetric apparatus book, John Chapman, Testing of glass volumetric apparatus. Washington, U.S. Dept. of Commerce, National Bureau of. Additional Physical Format: Online version: Peffer, Elmer Line, Testing of glass volumetric apparatus.

Washington, U.S. Govt. Print. Off.,   Report issued by the Bureau of Standards over testing conducted on volumetric glass apparatus. Types of glass apparatus being tested are presented and discussed.

The results of the testing are also discussed. This report Cited by: 1. TestingofGlassVoliunctricApparatus, The graduationsshouldbe of uniform width,continuous and finely but distinctlyetched, andmust beperpendicular to theaxis of the.

Laboratory glassware - Volumetric glassware - Methods for use and testing of capacity Verrerie de labora toire - Verrerie volum&rigue - Mhthodes d’utlJlsation et de v&ifica tion la capacith First edition - UDC Ref. IS0 (E). Cleaning of Glassware.

Labware Washing Machines. Volumetric glassware must be washed and dried before use as unclean glassware can introduce contamination errors. Soak used glassware in water and drain.

Clean with a cleaning detergent. Rinse with dilute potassium dichromate solution in sulphuric acid. Use— To attain the degree of precision required in many Pharmacopeial assays involving volumetric measurements and directing that a quantity be “accurately measured,” the apparatus must be chosen and used with care.

A buret should be of such size that the titrant volume represents not less than 30% of the nominal volume. Where less than 10 mL of titrant is to be. Calibration of laboratory glass ware class A and class B, pipette / graduated pipette / burette and volumetric flasks.

Tolerance limit and Frequency of Calibration. Weigh a clean & dry volumetric flask. Calibrate the flask by filling it with recently boiled and cooled distilled water at room temperature up to the mark and weigh the flask.

Download PDF: Sorry, we are unable to provide the full text but you may find it at the following location(s): (external link) http Author: United States.#N# Bureau of Standards. matography, heavy metals determination, test for glass containers for injections, infrared spectrophotometry, Use hard glass apparatus as illustrated in Fig.

Ground glass may be used for the joints. (2) Reagent glass-stoppered, volumetric cylinder D. By reference to Tablea suitable volume of distillate. ISO “Laboratory glassware -- Volumetric instruments -- Methods for testing of capacity and for use” 5.

OIML R 43 Edition (E) “Standard graduated glass flasks for verification officers” 6. OIML D 26 Edition (E) “Glass delivery measures - File Size: KB. News A quick guide to Classifications of Laboratory Glassware.

Laboratory glassware can be manufactured from Borosilicate and Soda-lime glass. Soda lime glass is generally used for Class B products or where long term exposure to chemicals is unlikely, e.g. one mark pipettes. Class A Borosilicate volumetric glassware has superior thermal and.

E Specification for Laboratory Glass Volumetric Flasks E Practice for Sampling Industrial Chemcials NIST Publication: Circular Testing of Glass Volumetric Apparatus 3. Summary of Test Method This test method is based upon a three-point adsorption isotherm (see Practisces D). AFile Size: 38KB. This International Standard provides methods for the testing, calibration and use of volumetric instruments made from glass in order to obtain the best accuracy in use.

NOTE Testing is the process by which the conformity of the individual volumetric instrument with the appropriate standard is determined, culminating in the determination of its. TEST METHOD FOR WATER AND SEDIMENT IN FUEL OILS BY THE CENTRIFUGE METHOD (LABORATORY PROCEDURE) ASTM D R Standard Test Method for Water and Sediment in Fuel Oils by the Centrifuge Method (Laboratory Procedure) ASTM E SPECIFICATION FOR LABORATORY GLASS VOLUMETRIC FLASKS, SPECIAL USE:.

NOTE General requirements and definitions of terms of piston-operated volumetric apparatus are given in ISO Conformity testing (type evaluation) of piston-operated volumetric apparatus is given in ISO Alternative test methods su ch as photometric and titrimetric methods will be the subject of a future Part 7 to ISO File Size: KB.

Standardization of devices and apparatus for laboratory purposes, with respect to principles and to materials of construction, performance, dimensions and testing, as well as the terms and definitions used in connection therewith.

The relative emphasis to be placed on standards of performance and on. Glass volumetric pipets are also known as transfer pipets. Calibrated “to deliver” (TD), and no “blow-out” is required to accurately empty the pipet.

Four sizes are available. See more product details. Options: (Select option to see volume pricing availability). All volumetric glassware for quantitative work requires calibration. 6. Range All volumetric glassware used for accurate delivery or to contain specific volumes needs to be calibrated.

7. Apparatus and Equipment Analytical balance accurate to mg (g) Analytical balance accurate to g. (For volumes of mL or less, the balance File Size: KB.A volumetric flask (measuring flask or graduated flask) is a piece of laboratory apparatus, a type of laboratory flask, calibrated to contain a precise volume at a certain temperature.

Volumetric flasks are used for precise dilutions and preparation of standard solutions. These flasks are usually pear-shaped, with a flat bottom, and made of glass or plastic.A graduated cylinder is a relatively slim glass or plastic cylinder used specifically for calibrating beakers or measuring a liquid's volume.

Graduated cylinders come in a variety of sizes such as 10 ml, 25 ml, 50 ml, ml, ml and 1, ml. Scientists take measurements by viewing, at eye-level, the lowest point of the convex dip that the.